Giant coronary artery aneurysm in an adult
Free
  1. Gailin Bronson Sebastian,
  2. Jithu Sam Rajan,
  3. Ashraf Safiya Manzil
  1. Department of Cardiology, Pariyaram Medical College, Kannur, Kerala, India
  1. Correspondence to Dr Gailin Bronson Sebastian, Department of Cardiology, Pariyaram Medical College, Kannur, Kerala 670503, India; gailinbs{at}yahoo.co.in

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

A 56-year-old man presented with effort angina of 2 months’ duration. Coronary angiogram revealed a tight tubular stenosis in proximal left anterior descending artery (LAD), followed by a giant, wide-mouthed, saccular aneurysm measuring 16×14 mm (figure 1). As the cardiac surgeons speculated difficulty in accessing the site, a percutaneous coronary intervention was planned. The left main coronary artery was engaged using an 8F Judkins left 3.5 guiding catheter. After predilatation with a 2.5×10 mm balloon (Sprinter) and an intravascular ultrasound (IVUS) study (figures 2 and 3), a 4×16 mm polytetrafluoroethylene (PTFE)-covered stent (Graft Master, Jostent) was deployed at 16 bars for 22 s. Since the subsequent angiogram revealed a residual leak into the distal portion of the aneurysm (figure 4), another 3.5×15 mm PTFE-covered stent (Prograft) was deployed distally in an overlapping fashion at 16 bars for 20 s. Postdilatation was done using a 4×9 mm non-compliant balloon (NC Sprinter). The final angiogram revealed no residual stenosis and a successful exclusion of the aneurysm from the native coronary artery (figures 5 and 6).

Figure 1

Right anterior oblique caudal view of the left anterior descending artery at baseline, showing proximal tubular stenosis (arrow) followed by a giant aneurysm (bold arrow).

Figure 2

Intravascular ultrasound image of the aneurysm in the left anterior descending artery, the borders of which are marked with white arrows.

Figure 3

Intravascular ultrasound-chroma flow image showing the aneurysm in the left anterior descending artery, the borders of which have been marked with white arrows.

Figure 4

Check coronary angiogram (right anterior oblique; caudal view) after placement of the first covered stent showing residual leak (black arrow) into the aneurysm distal to the stent.

Figure 5

Angiogram after polytetrafluoroethylene-covered stents placement showing a peculiar ‘blood-dye’ level (black arrow) as the trapped dye settles within the aneurysm confirming its complete exclusion from the native coronary artery lumen.

Figure 6

Coronary angiogram (left anterior oblique; caudal view) confirming successful exclusion of the aneurysm that still contains dye (black arrow) from the left anterior descending artery after placement of covered stents.

Coronary aneurysm is defined as localised dilatation of artery to more than 1.5 times the adjacent normal segment. A coronary artery aneurysm is termed ‘giant’ when its diameter exceeds 8 mm or is more than four times the size of the reference vessel.1 They are uncommon in adults, the major causes being atherosclerosis, Kawasaki disease, trauma, inflammatory disorders (eg, polyarteritis nodosa), connective tissue disorders (eg, Marfan syndrome) and iatrogenic causes. Surgery had been the classically described management, but aneurysmal exclusion using covered stent is a novel and effective alternative therapy.2